sadasd ha inviato un aggiornamento 3 anni, 1 mese fa
Dust-extraction systems were attached to the packaging machines, the sugar screening equipment, and the mills for powdered-sugar production, to remove sugar dust. The dust-extraction ducts were connected to dry dust collectors. However, it was found that the maintenance of the dust-collection system had been poor. In addition, some equipment was significantly undersized or incorrectly installed. Some dust ducts were found to be partially, and in some locations, completely filled with sugar dust.
The plant had hired an outside consultant to evaluate airflows, pressure drops, and other operating parameters on both the dry and the wet dust-collection systems. The report identified numerous design and maintenance deficiencies. Because the report was delivered only a few days before the 2008 catastrophe, there had been no opportunity to review or act on it.