The performance of a centrifugal fan with enlarged impeller
The influence of enlarged impeller in unchanged volute on G4-73 type centrifugal fan performance is investigated in this paper. Comparisons are conducted between the fan
with original impeller and two larger impellers with the increments in impeller outlet diameter of 5% and 10% respectively in
the numerical and experimental investigations. The internal characteristics are obtained by the numerical simulation, which
indicate there is more volute loss in the fan with larger impeller. Experiment results show that the flow rate, total
pressure rise, shaft power and sound pressure level have increased, while the efficiency have decreased when the fan operates
with larger impeller. Variation equations on the performance of the operation points for the fan with enlarged impellers are
suggested. Comparisons between experiment results and the trimming laws show that the trimming laws for usual situation can
predict the performance of the enlarged fan impeller with less error for higher flow rate, although the situation of
application is not in agreement. The noise frequency analysis shows that higher noise level with the larger impeller fan is
caused by the reduced impeller–volute gap.